The WAGO 2002-1392 is an orange end/intermediate plate designed for use with the 2002-13xx series terminal blocks. It is 0.8 mm wide and meets UL94 V0 flammability standards.
Product Model2002-1392
Product ID47304
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureDesigned for 2002-13xx series terminal blocks
2
FeatureOrange color for easy identification
3
FeatureMeets UL94 V0 flammability standards
4
FeatureCompact 0.8 mm width
5
FeatureSuitable for various industrial and building applications
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Width
0.8 mm / 0.031 inches
Height
59 mm / 2.323 inches
Depth
28.9 mm / 1.138 inches
Mounting type
snap-on type
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.043MJ
Weight
1.4g
Product Group
22 (TOPJOB S)
eCl@ss 10.0
27-14-11-33
eCl@ss 9.0
27-14-11-33
ETIM 9.0
EC000886
ETIM 8.0
EC000886
ECCN
NO US CLASSIFICATION
PU (SPU)
100 (25) pcs
Packaging type
box
Country of origin
CN
GTIN
4055143234221
Customs tariff number
8538906000
RoHS Compliance Status
Compliant,No Exemption
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category 1, Class A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed
WAGO 2002-1392 TOPJOB S End/Intermediate Plate | INDSLT