The Wago 2000-1392 is an end and intermediate plate designed for the 2000-13xx series terminal blocks. It is 0.7 mm thick and part of the TOPJOB S product group.
Product Model2000-1392
Product ID46209
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureDesigned for 2000-13xx series terminal blocks
2
Feature0.7 mm thickness for precise fitting
3
FeaturePart of the TOPJOB S product group
4
FeatureDurable construction for reliable use
5
FeatureAvailable in packs for convenience
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Width
0.7 mm / 0.028 inches
Height
57.8 mm / 2.273 inches
Depth
28.9 mm / 1.138 inches
Mounting type
snap-on type
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.041MJ
Weight
1.2g
Product Group
22 (TOPJOB S)
eCl@ss 10.0
27-14-11-33
eCl@ss 9.0
27-14-11-33
ETIM 9.0
EC000886
ETIM 8.0
EC000886
ECCN
NO US CLASSIFICATION
PU (SPU)
100 (25) pcs
Packaging type
box
Country of origin
DE
GTIN
4045454711337
Customs tariff number
8538906000
RoHS Compliance Status
Compliant,No Exemption
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category 1, Class A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment