The PFC200 Controller is a compact PLC for the modular WAGO-I/O-SYSTEM, supporting various network and fieldbus interfaces.
Product Model750-8204
Product ID45071
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureCompact design suitable for the modular WAGO-I/O-SYSTEM
2
Supports multiple network interfaces2 x ETHERNET, RS-232/-485, CAN, CANopen
3
FeatureIdeal for industrial automation and control applications
4
FeatureLightweight at 0.25kg for easy installation
5
FeatureRobust and reliable performance in various industrial environments
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Communications
CANopen
ETHERNET protocols
DHCP
Visualization
Web-Visu
Operating system
Real-time Linux (with PREEMPT_RT patch)
CPU
Cortex A8; 600 MHz
Programming languages per IEC 61131-3
Instruction List (IL)
Programming environment
e!COCKPIT(based on CODESYS V3)
Configuration options
e!COCKPIT
Transmission rate
ETHERNET: 10/100 mbit/s
Transmission medium (communication/fieldbus)
ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
Main memory (RAM)
256MB
Internal memory (flash)
256MB
Non-volatile hardware memory
128Kbytes
Program memory
CODESYS V2: 16 mB; CODESYS V3:?60 mB (Program and data memory (dynamically distributed))
Data memory
CODESYS V2: 64 mB; CODESYS V3:?60 mB?Program and data memory (dynamically distributed)
Non-volatile software memory
128.Kbytes
Type of memory card
SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO's memory card)
Memory card slot
Push-push mechanism; Cover lid (sealable)
Number of modules per node (max.)
250
Number of modules without a bus extension (max.)
64
Input and output process image (internal) max.
1000 Words/1000 Words
Input and output process image (Modbus®) max.
CODESYS V2: 1000 Words/1000 Words
Input and output process image (CAN) max.
2000 Words/2000 Words
Indicators
LED (SYS, RUN, I/O, CAN, U1 U6) red/green/orange: Status system, program, internal data bus, CANopen, status programmable by user (can be used via CODESYS library); LED (A, B) green: Status system power supply, field supply
Supply voltage (system)
24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Input current (typ.) at nominal load (24 V)
550mA
Total current (system supply)
1,700mA
Supply voltage (field)
24 VDC (-25 +30 %); Via power jumper contacts
Current carrying capacity (power jumper contacts)
10A
Number of outgoing power jumper contacts
3
Isolation
500 V system/field
Connection technology: communication/fieldbus
CANopen: 1 x D-sub 9 plug; modbus (TCP, UDP): 2 x RJ-45; modbus RTU: 1 x D-sub 9 socket; RS-232 serial interface: 1 x D-sub 9 socket; RS-4852 interface: 1 x D-sub 9 socket
Connection technology: system supply
2 x CAGE CLAMP®
Connection technology: field supply
6 x CAGE CLAMP®
Connection type 1
System/field supply
Solid conductor
0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor
0.08 … 2.5 mm2 / 28 14 AWG
Strip length
8 9 mm / 0.31 0.35 inches
Connection technology: device configuration
1 x Male connector; 4-pole
Width
112 mm / 4.409 inches
Height
71.9 mm / 2.831 inches
Depth
100 mm / 3.937 inches
Weight
246.7g
Color
light gray
Housing material
Polycarbonate; polyamide 6.6
Conformity marking
CE
Ambient temperature (operation)
0 … +55 °C
Ambient temperature (storage)
-40 … 85 °C
Protection type
IP20
Pollution degree
2 per IEC 61131-2
Operating altitude
without temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation)
95%
Mounting position
Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Mounting type
DIN-35 rail
Vibration resistance
4g per IEC 60068-2-6
Shock resistance
15g per IEC 60068-2-27
EMC immunity to interference
per EN 61000-6-2, marine applications
EMC emission of interference
per EN 61000-6-3, marine applications
Exposure to pollutants
Per IEC 60068-2-42 and IEC 60068-2-43
Fire load
2.883MJ
Permissible pollutant concentration H2S at a relative humidity < 75%
10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%