FeatureCAGE CLAMP® spring pressure connection technology
3
FeatureSuitable for solid, stranded, and fine-stranded conductors
4
FeatureEasy push-in termination without tools
5
FeatureVibration-proof and fast connection solutions
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Communications
EtherNet/IPTM
ETHERNET protocols
HTTP
Visualization
Web-Visu
CPU
32 bits
Programming languages per IEC 61131-3
Instruction List (IL)
Programming environment
WAGO-I/O-PROV2.3 (based on CODESYS V2.3)
Configuration options
WAGO-I/O-CHECK
Transmission rate
10/100 mbit/s
Transmission medium (communication/fieldbus)
Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
Transmission performance
Class D per EN 50173
Program memory
1024 KB
Data memory
1024 KB
Non-volatile software memory
32Kbytes
Type of memory card
SD card
Memory card slot
Push-push mechanism; Cover lid (sealable)
Number of modules per node (max.)
64
Input and output process image (fieldbus) max.
1020 Words/1020 Words
Indicators
LED (LINK/ACT) green: Network connection via ports 1 2; LED (MS, NS) red/green: Status of node, network; LED (I/O, USR) red/green/orange: Local data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply
Derating
Total current (system supply):1700°mA (ambient temperature (operation) < 60°°C);1500 mA (ambient temperature (operation): 60 70 °C);Derating (supply voltage):Ambient temperature under laboratory conditions: (?25 +30 %);for ?40 … +55 °C: 24 V (?25 +20 %);for +55 … +70 °C: 24 V (?25 +10 %);Lower limit in all temperature ranges: ?27.5 % (including 15 % residual ripple)
Supply voltage (system)
24 VDC; Via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
Input current (typ.) at nominal load (24 V)
500mA
Power supply efficiency (typ.) at nominal load (24 V)
90%
Current consumption (5 V system supply)
450mA
Total current (system supply)
1,700mA
Supply voltage (field)
24 VDC;?Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
Current carrying capacity (power jumper contacts)
10A
Number of outgoing power jumper contacts
2
Ratings per
IEC/EN 60664-1
Rated surge voltage
1 kV
Connection technology: communication/fieldbus
EtherNet/IPTM: 2 x RJ-45; Modbus (TCP, UDP): 2 x RJ-45
Connection technology: system supply
2 x CAGE CLAMP®
Connection technology: field supply
4 x CAGE CLAMP®
Connection type 1
System/field supply
Solid conductor
0.25 2.5 m㎡/ 24 14 AWG
Fine-stranded conductor
0.25 2.5 m㎡/ 24 14 AWG
Strip length
8 9 mm / 0.31 0.35 inches
Connection technology: device configuration
1 x Male connector; 4-pole
Width
61.5 mm / 2.421 inches
Height
100 mm / 3.937 inches
Depth
71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail
64.7 mm / 2.547 inches
Weight
167g
Color
dark gray
Housing material
Polycarbonate; polyamide 6.6
Conformity marking
CE
Ambient temperature (operation)
-40 … +70 °C
Ambient temperature (storage)
-40 … 85 °C
Protection type
IP20
Pollution degree
2 per IEC 61131-2
Operating altitude
without temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation)
95%
Relative humidity (with condensation)
Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
Mounting position
Horizontal left, horizontal up, vertical top and vertical bottom
Mounting type
DIN-35 rail
Vibration resistance
per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
Shock resistance
per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
EMC immunity to interference
per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
EMC emission of interference
per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutants
Per IEC 60068-2-42 and IEC 60068-2-43
Fire load
2.457MJ
Permissible pollutant concentration H2S at a relative humidity < 75%
10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%