The push-in type jumper bar system is based on the common plug and socket principle. Each terminal block is spring-loaded with a.
Product Model2016-404
Product ID41163
Stock on Request
Last updated: 8/29/2026
Key Features
1
{1. Insulated for SafetyThe jumper is insulated to ensure safe operation.}, {2. Spring-Loaded Terminals: Each terminal block is spring-loaded for easy connection.}, {3. Push-In Type: Easy to use push-in type jumper bar system.}, {4. Versatile Applications: Suitable for various applications due to its design.}, {5. High-Quality Material: Made from high-quality materials for durability.}
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Width
45.5 mm / 1.791 inches
Height
4.1 mm / 0.161 inches
Depth
23 mm / 0.906 inches
Jumper assignment
1-2-3-4
Note (material data)
Information on material specifications can be found here
Color
light gray
Fire load
0.039MJ
Weight
10.2g
Product Group
22 (TOPJOB S)
eCl@ss 10.0
27-14-11-40
eCl@ss 9.0
27-14-11-40
ETIM 9.0
EC000489
ETIM 8.0
EC000489
ECCN
NO US CLASSIFICATION
PU (SPU)
25 pcs
Packaging type
bag
Country of origin
DE
GTIN
4055143702119
Customs tariff number
8536698000
RoHS Compliance Status
Compliant,No Exemption
Rated voltage (III / 3)
800V
Rated current
76A
Rated current (Ex e II)
65A
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category 1, Class A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment