For 2002 series carrier terminal blocks; orange (4045454866020) Online at WAGO USA!
Product Model2002-401
Product ID40089
Stock on Request
Last updated: 8/29/2026
Key Features
1
{Point 1Designed for 2002 series carrier terminal blocks}, {Point 2: Orange color for easy identification}, {Point 3: Reliable disconnection and connection mechanism}, {Point 4: Ideal for use with DIN-rail 35 x 15 and 35 x 7.5}, {Point 5: Push-in CAGE CLAMP technology}
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Note (material data)
Information on material specifications can be found here
Color
orange
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.01MJ
Weight
0.6g
Continuous operating temperature
105 °C
Product Group
22 (TOPJOB S)
eCl@ss 10.0
27-14-11-92
eCl@ss 9.0
27-14-11-92
ETIM 9.0
EC002848
ETIM 8.0
EC002848
ECCN
NO US CLASSIFICATION
PU (SPU)
100 pcs
Packaging type
box
Country of origin
DE
GTIN
4045454866020
Customs tariff number
8536694040
RoHS Compliance Status
Compliant,No Exemption
Rated surge voltage (III/2)
6kV
Rated current
10A
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category 1, Class A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment