FeatureIdeal for various applications including industrial and residential settings.
5
FeatureEasy to install and maintain with its modular design.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
Harmony XB4
Product or Component Type
Triple-headed push-button
Device short name
XB4
Bezel material
Chromium plated metal
Fixing collar material
Zamak
Head type
Standard
Mounting diameter
0.9 in (22.5 mm)
Shape of signaling unit head
Rectangular
Type of operator
spring return
Operator profile
Red projecting, STOP white)Green flush, I white)Green flush, II white)
Operators description
Green ''I'' - green ''II'' - red ''STOP''
Contacts type and composition
1 NO + 1 NC + 1 NO
Contact operation
Slow-break
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1Screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1Spring terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1Spring terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
Net Weight
0.282 lb(US) (0.128 kg)
Resistance to high pressure washer
1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
Colour of marking
Black marking when white capsWhite marking when green, red or black caps
Contacts usage
Standard contacts
Positive opening
With IEC 60947-5-1 appendix K
Operating travel
0.06 in (1.5 mm) NC changing electrical state)0.1 in (2.6 mm) NO changing electrical state)0.2 in (4.3 mm) total travel)
Operating force
3.5 N NC changing electrical state3.8 N NO changing electrical state
Mechanical durability
1000000 cycles
Tightening torque
7.08...10.6 lbf.in (0.8...1.2 N.m) IEC 60947-1
Shape of screw head
Cross JIS No 1Cross Philips no 1Cross pozidriv No 1Slotted flat à 4 mmSlotted flat à 5.5 mm
Contacts material
Silver alloy (Ag/Ni)
Short-circuit protection
10 A cartridge fuse gG IEC 60947-5-1
[Ith] conventional free air thermal current
10 A IEC 60947-5-1
[Ui] rated insulation voltage
600 V 3)IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A600 IEC 60947-5-16 A 120 V, AC-15, A600 IEC 60947-5-10.1 A 600 V, DC-13, Q600 IEC 60947-5-10.27 A 250 V, DC-13, Q600 IEC 60947-5-10.55 A 125 V, DC-13, Q600 IEC 60947-5-11.2 A 600 V, AC-15, A600 IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
Electrical reliability
Î < 10exp(-6) 5 V 1 mA in clean environment IEC 60947-5-4Î < 10exp(-8) 17 V 5 mA in clean environment IEC 60947-5-4