Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
Modicon Premium Automation platform
Product or Component Type
Discrete output module
Discrete output number
16
Discrete output type
Relay not protected
Discrete output voltage
12...24 V DC EN/IEC 61131-2 10...34 V24...240 V AC EN/IEC 61131-2 20...264 V
[Ith] conventional free air thermal current
3 A
Response time
< 10 ms (deactivation)< 8 ms (activation)
Contacts type and composition
1 NO
Output overvoltage protection
DC inductive, by discharge diode on each preactuatorAC inductive, by RC circuit MOV (ZNO) on each preactuator
Output overload protection
1 external fuse per channel or group of channel fast blow
Short-circuit protection
1 external fuse per channel or group of channel fast blow
isalotion resistance
> 10 MOhm 500 V
Power dissipation
(0.25 W + 0.2 W x No of outputs at state 1)
Electrical durability
1000000 cycles DC-12 24 W 24 V resistive1000000 cycles DC-3 24 W 24 V inductive2000000 cycles DC-3 10 W 24 V inductive300000 cycles DC-12 40 W 24 V resistive100000 cycles AC-14 220 VA 220 V inductive100000 cycles AC-15 220 VA 220 V inductive1000000 cycles AC-12 110 VA 110 V resistive1000000 cycles AC-12 220 VA 220 V resistive1000000 cycles AC-12 50 VA 48 V resistive1000000 cycles AC-14 110 VA 220 V inductive1000000 cycles AC-15 110 VA 220 V inductive150000 cycles AC-14 110 VA 110 V inductive150000 cycles AC-15 110 VA 110 V inductive1500000 cycles AC-14 50 VA 110 V inductive1500000 cycles AC-15 50 VA 110 V inductive2000000 cycles AC-14 24 VA 48 V inductive2000000 cycles AC-15 24 VA 48 V inductive3000000 cycles AC-14 50 VA 220 V inductive3000000 cycles AC-15 50 VA 220 V inductive500000 cycles AC-12 110 VA 48 V resistive500000 cycles AC-12 220 VA 110 V resistive500000 cycles AC-14 24 VA 24 V inductive500000 cycles AC-15 24 VA 24 V inductive5000000 cycles AC-14 10 VA 110 V inductive5000000 cycles AC-14 10 VA 220 V inductive5000000 cycles AC-14 10 VA 48 V inductive5000000 cycles AC-15 10 VA 110 V inductive5000000 cycles AC-15 10 VA 220 V inductive5000000 cycles AC-15 10 VA 48 V inductive700000 cycles AC-12 50 VA 24 V resistive
marking
CE
Electrical connection
Screw terminal block
Current consumption
135 mA 24 V DC rack80 mA 5 V DC
Module format
Standard
Net Weight
0.84 lb(US) (0.38 kg)
Dielectric strength
2000 V 50/60 Hz 60 s
Standards
73/23/EECIEC 61131-2UL 508CSA C22.2 No 213 Class I Division 2 Group B92/31/EEC89/336/EECCSA C22.2 No 213 Class I Division 2 Group CCSA C22.2 No 213 Class I Division 2 Group ACSA C22.2 No 142CSA C22.2 No 213 Class I Division 2 Group D93/68/EEC
Product Certifications
BVRINALRABSRMRSGLDNV
Ambient Air Temperature for Operation
32...140 °F (0...60 °C)
Ambient Air Temperature for Storage
-13...158 °F (-25...70 °C)
Relative Humidity
10...95 % without condensation for operation5...95 % without condensation for storage
Operating altitude
0...6561.68 ft (0...2000 m)
Protective treatment
TC
IP Degree of Protection
IP20
Pollution degree
2
TSXDSY16R5 Discrete Output Module by Schneider Electric | INDSLT