The TMC4TI2 analogue input cartridge by Schneider Electric offers 14-bit resolution and 2 temperature inputs, compatible with Modicon M241C PLC.
Product ModelTMC4TI2
Product ID34724
Stock on Request
Last updated: 8/29/2026
Key Features
1
Feature14-bit analogue input resolution for precise temperature measurements.
2
Feature2 temperature inputs for dual-channel monitoring.
3
FeatureCompatible with Modicon M241C PLC for seamless integration.
4
FeatureRobust and reliable performance in industrial environments.
5
FeatureEasy configuration and maintenance via EcoStruxure Machine Expert.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
Modicon M241
Product or Component Type
Analogue input cartridge
Product Compatibility
Modicon M241C
Analogue input number
2
Analogue input type
thermocouple - 200...1000 °C thermocouple J thermocouple - 200...1300 °C thermocouple K thermocouple 0...1760 °C thermocouple R thermocouple 0...1760 °C thermocouple S thermocouple 0...1820 °C thermocouple B thermocouple - 200...400 °C thermocouple T thermocouple - 200...1300 °C thermocouple N thermocouple - 200...800 °C thermocouple ENi 100/Ni 1000 temperature probe - 60...180 °CPt 100 temperature probe - 200...850 °CPt 1000 temperature probe - 200...600 °C
Analogue input resolution
14 bits
LSB value
0.1 °C
Sampling duration
100 ms
Absolute accuracy error
+/- 0.5 % of full scale at 77 °F (25 °C) for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple K - 200...1300 °C+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple J - 200...1000 °C+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple E - 200...800 °C+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple T - 200...400 °C+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple N - 200...1300 °C+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple B 250...400 °C+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple B 400...1280 °C+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple R, S 0...1760°C
Temperature Drift
+/- 0.008 %FS/°C
Repeat accuracy
+/- 0.1 %FS
Non-linearity
+/- 0.05 %FS
Cross talk
80 dB
Type of Cable
Twisted shielded pairs cable
Electrical connection
1 x 1.5 mm² 1 spring terminal block pitch 3.81 mm for outputs and supply
Maximum cable distance between devices
Twisted shielded pairs cable <98.4 ft (30 m) input
Insulation
Between input and internal logic 500 V DCNon-insulated between inputs