<= 0.05 % per degree centigrade depending permissible ambient air temperature<= 1 % within the supply voltage range
Setting accuracy of time delay
10 P
Time delay drift
<= 0.05 % per degree centigrade depending permissible ambient air temperature<= 1 % within the supply voltage range
Hysteresis
5...50 % adjustable threshold setting3 % fixed full scale for window mode
delay at power up
0.3 s
Repeat accuracy
+/- 0.5 % input and measurement circuit+/- 2 % time delay
Measurement error
< 1 % over the whole range with voltage variation0.05 %/°C with temperature variation
Response time
<= 500 ms (on crossing the threshold)
Threshold setting
10...100 %
Overvoltage category
III IEC 60664-1III UL 508
Insulation resistance
> 100 MOhm 500 V DC IEC 60255-27
Insulation
Between supply and measurement
Connections - terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable endScrew terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable endScrew terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable endScrew terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Tightening torque
5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1
Housing material
Self-extinguishing plastic
Local signalling
for relay ON LED (yellow) for power ON LED (green)
Mounting support
35 mm DIN rail conforming to IEC 60715
Electrical durability
100000 cycles
Mechanical durability
10000000 cycles
[Un] rated nominal voltage
24...240 V AC/DC 50/60 Hz, non self-powered
Safety reliability data
MTTFd = 296.8 yearsB10d = 270000
Contacts material
Cadmium free
Width
1.4 in (35 mm)
Control Type
With test button
Net Weight
0.26 lb(US) (0.12 kg)
Immunity to microbreaks
50 ms
Electromagnetic compatibility
Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1Immunity for industrial environments conforming to IEC 61000-6-2Emission standard for industrial environments conforming to IEC 61000-6-4Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5Conducted and radiated emissions class B group 1 conforming to CISPR 11Conducted and radiated emissions class B conforming to CISPR 22Emission standard for residential, commercial and light-industrial environments (except radiated emission) conforming to IEC 61000-6-3
0.075 mm 10...58.1 Hz) not in operation IEC 60068-2-61 gn 10...58.1 Hz) not in operation IEC 60068-2-60.035 mm 58.1...150 Hz) in operation IEC 60068-2-60.5 gn 58.1...150 Hz) in operation IEC 60068-2-6
Shock resistance
15 gn 11 ms) not in operation IEC 60068-2-275 gn 11 ms) in operation IEC 60068-2-27