< 1 % over the whole range with voltage variation0.05 %/°C with temperature variation
Maximum cable distance between devices
3280.8 ft (1000 m) probe and delay
Sensitivity scale
5...100 kOhm St (Standard Sensitivity)
Sensitivity adjustment
5...100 %
Maximum supply current for sensors
1 mA
Cable capacitance
1 nF HS (High Sensitivity) probe cable2.2 nF St (Standard Sensitivity) probe cable4.7 nF LS (Low Sensitivity) probe cable
Overvoltage category
III IEC 60664-1
Insulation
Between supply and measurement
Connections - terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable endScrew terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable endScrew terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable endScrew terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Tightening torque
5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1
Housing material
Self-extinguishing plastic
Mounting support
35 mm DIN rail conforming to IEC 60715
Mounting position
Any position
Electrical durability
100000 cycles
Mechanical durability
10000000 cycles
Contacts material
Cadmium free
Measurement range
5...100 kOhm
Safety reliability data
B10d = 120000MTTFd = 125.5 years
Width
0.9 in (22.5 mm)
Control Type
With test button
Net Weight
0.2 lb(US) (0.1 kg)
Immunity to microbreaks
100 ms DC90 ms AC
Electromagnetic compatibility
Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1Immunity for industrial environments conforming to IEC 61000-6-2Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3Emission standard for industrial environments conforming to IEC 61000-6-4Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5Conducted and radiated emissions class B group 1 conforming to CISPR 11Conducted and radiated emissions class B conforming to CISPR 22
Standards
IEC 60255-1
Product Certifications
GLRCMCCCCSAULEACCE
Ambient Air Temperature for Storage
-40...158 °F (-40...70 °C)
Relative humidity
93...97 % 77...131 °F (25...55 °C) IEC 60068-2-30
Vibration resistance
0.075 mm 10...58.1 Hz) not in operation IEC 60068-2-61 gn 10...58.1 Hz) not in operation IEC 60068-2-60.035 mm 58.1...150 Hz) in operation IEC 60068-2-60.5 gn 58.1...150 Hz) in operation IEC 60068-2-6
Shock resistance
15 gn 11 ms) not in operation IEC 60068-2-275 gn 11 ms) in operation IEC 60068-2-27