The LC1F7804 contactor by Schneider Electric is a reliable and efficient solution for various applications.
Product ModelLC1F7804
Product ID33512
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureHigh current rating for demanding applications
2
FeatureWide voltage compatibility for flexibility in setup
3
FeatureDurable design for long-lasting performance
4
FeatureEasy integration with control circuits
5
FeatureComprehensive range of control options
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range
TeSys
Product name
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
power pole contact composition
4 NO
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
[Ie] rated operational current
1600 A 104 °F (40 °C)) <= 440 V AC AC-1
[Uc] control circuit voltage
110...500 V AC 40...400 Hz with LX1/LX9 coil48...440 V DC with LX4 coil
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
1600 A (at 104 °F (40 °C))
Irms rated making capacity
7800 A AC conforming to IEC 60947-4-1
Rated breaking capacity
6240 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3000 A 104 °F (40 °C) - 3 min6250 A 104 °F (40 °C) - 10 s5600 A 104 °F (40 °C) - 30 s4600 A 104 °F (40 °C) - 1 min2200 A 104 °F (40 °C) - 10 min
Associated fuse rating
800 A aM at <= 440 V1600 A gG at <= 440 V
Average impedance
0.1 mOhm - Ith 1600 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole
250 W AC-1
Control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coilDrop-out: 0.2...0.4 Uc AC 40...400 Hz with LX1/LX9 coilOperational: 0.85...1.1 Uc DC with LX4 coilDrop-out: 0.2...0.4 Uc DC with LX4 coil
Heat dissipation
22 W
Operating time
40...80 ms closing with LX1/LX9 coil130...230 ms opening with LX1/LX9 coil70...80 ms closing with LX4 coil100...130 ms opening with LX4 coil
1900...2300 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil1960...2420 VA (at 68 °F (20 °C))with LX4 coil
Hold-in power consumption in VA
44...55 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil42...52 VA (at 68 °F (20 °C))with LX4 coil
Maximum operating rate
600 cyc/h 131 °F (55 °C)
compatibility code
LC1F
IP degree of protection
IP20 front face with shrouds IEC 60529IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23...131 °F (-5...55 °C)
Ambient Air Temperature for Storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
-40...158 °F (-40...70 °C)
Operating altitude
9842.52 ft (3000 m) without derating
Mechanical robustness
Vibrations contactor open2.5 Gn, 5...300 HzVibrations contactor closed5.5 Gn, 5...300 HzShocks contactor open5 Gn for 1/2 sine wave (11 ms)Shocks contactor closed15 Gn for 1/2 sine wave (11 ms)