Search manufacturers, products
Home
Manufacturers
Request Quote
Support
Shipping & Delivery
Refund & Return
Purchase Guide
About Us
Contact Us
Home
Schneider
Industrial Automation and Control
Contactors and Protection Relays
LC1F4004Q7
Schneider
Contactors and Protection Relays
LC1F4004Q7
Product Model
LC1F4004Q7
Product ID
33440
Stock on Request
Last updated: 8/29/2026
Quantity
−
+
Add to RFQ
Request Quote Now
Key Features
1
Feature
-
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<= 460 V DC
[Uc] control circuit voltage
380 V AC 40...400 Hz
[Ie] rated operational current
500 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
500 A (at 104 °F (40 °C))
Rated breaking capacity
3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3600 A 104 °F (40 °C) - 10 s2400 A 104 °F (40 °C) - 30 s1700 A 104 °F (40 °C) - 1 min1200 A 104 °F (40 °C) - 3 min1000 A 104 °F (40 °C) - 10 min
Associated fuse rating
400 A aM at <= 440 V500 A gG at <= 440 V
Average impedance
0.26 mOhm - Ith 500 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole
65 W AC-1
Overvoltage category
III
power pole contact composition
4 NO
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability
10 Mcycles
Inrush power in VA
1075 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA
15 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Operating time
40...65 ms closing100...170 ms opening
Connections - terminals
Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable endControl circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable endControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable endControl circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable endControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable endControl circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable endPower circuit bar 2 30 x 5 mmPower circuit lugs-ring terminals 2 0.2 in² (150 mm²)Power circuit bolted connection
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)Power circuit 309.8 lbf.in (35 N.m)
Mounting Support
Plate
Heat dissipation
14 W
Standards
JIS C8201-4-1EN 60947-1IEC 60947-4-1EN 60947-4-1IEC 60947-1
Product Certifications
LROS (Lloyds register of shipping)RMRoSRINACCCBVABSDNVULCBUKCA
compatibility code
LC1F
Control circuit type
AC 40...400 Hz
IP degree of protection
IP20 front face with shrouds IEC 60529IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23...131 °F (-5...55 °C)
Ambient Air Temperature for Storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
-40...158 °F (-40...70 °C)
Height
8.1 in (206 mm)
Width
10.3 in (261 mm)
Depth
8.6 in (219 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
22.5 lb(US) (10.2 kg)