High power TeSys F contactor designed for applications up to 440V and 700A, with LX1/LX9 coil options.
Product ModelLC1F5002
Product ID33263
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureHigh power handling up to 700A
2
FeatureSuitable for applications up to 440V
3
FeatureWide band AC/DC coil options (LX1/LX9)
4
FeatureCompact design for efficient use in various settings
5
FeatureReliable performance in demanding electrical systems
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range
TeSys
Product name
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
2P
power pole contact composition
2 NO
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
[Ie] rated operational current
700 A 104 °F (40 °C)) <= 440 V AC AC-1
[Uc] control circuit voltage
48...1000 V AC 40...400 Hz with LX1/LX9 coil48...440 V DC with LX4 coil
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
700 A (at 104 °F (40 °C))
Irms rated making capacity
5000 A AC conforming to IEC 60947-4-1
Rated breaking capacity
4000 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
4200 A 104 °F (40 °C) - 10 s3200 A 104 °F (40 °C) - 30 s2400 A 104 °F (40 °C) - 1 min1500 A 104 °F (40 °C) - 3 min1200 A 104 °F (40 °C) - 10 min
Associated fuse rating
500 A aM at <= 440 V800 A gG at <= 440 V
Average impedance
0.18 mOhm - Ith 700 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole
88 W AC-1
Control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coilDrop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coilOperational: 0.85...1.1 Uc DC with LX4 coilDrop-out: 0.2...0.35 Uc DC with LX4 coil
Heat dissipation
18 W
Operating time
40...75 ms closing with LX1/LX9 coil100...170 ms opening with LX1/LX9 coil50...60 ms closing with LX4 coil45...60 ms opening with LX4 coil
Mounting Support
Plate
Standards
JIS C8201-4-1EN 60947-1IEC 60947-1EN 60947-4-1IEC 60947-4-1
Product Certifications
CSALROS (Lloyds register of shipping)DNVBVABSCBRMRoSRINAULUKCA
1050...1150 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil990...1220 VA (at 68 °F (20 °C))with LX4 coil
Hold-in power consumption in VA
16...20 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil4.54...8 VA (at 68 °F (20 °C))with LX4 coil
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
compatibility code
LC1F
IP degree of protection
IP20 front face with shrouds IEC 60529IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23...131 °F (-5...55 °C)
Ambient Air Temperature for Storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
-40...158 °F (-40...70 °C)
Operating altitude
9842.52 ft (3000 m) without derating
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed4 Gn, 5...300 HzShocks contactor open9 Gn for 1/2 sine wave (11 ms)Shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Height
9.4 in (238 mm)
Width
9.2 in (233 mm)
Depth
9.1 in (232 mm)
Net Weight
21.50 lb(US) (9.75 kg)