The LC1F185F722L TeSys F nonreversing contactor is a reliable solution for motor control and protection.
Product ModelLC1F185F722L
Product ID
33197
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureHigh reliability for motor control and protection
2
FeatureDesigned for 600V, 185A applications
3
FeatureSuitable for 110VAC, 50/60Hz coils
4
FeatureIdeal for non-reversing motor applications
5
FeatureEnhanced safety features for secure operation
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Motor controlResistive load
Utilisation category
AC-3AC-1
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage
110 V AC 40...400 Hz
[Ie] rated operational current
275 A (at <104 °F (40 °C)) at <= 440 V AC AC-1185 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
275 A (at 104 °F (40 °C))
Rated breaking capacity
1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
1500 A 104 °F (40 °C) - 10 s920 A 104 °F (40 °C) - 30 s740 A 104 °F (40 °C) - 1 min500 A 104 °F (40 °C) - 3 min400 A 104 °F (40 °C) - 10 min
Associated fuse rating
200 A aM at <= 440 V315 A gG at <= 440 V
Average impedance
0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole
12 W AC-325 W AC-1
Overvoltage category
III
power pole contact composition
3 NO
Auxiliary contact composition
2 NO + 2 NC
Motor power kW
90 kW at 380...400 V AC 50/60 Hz100 kW at 415 V AC 50/60 Hz100 kW at 440 V AC 50/60 Hz110 kW at 500 V AC 50/60 Hz110 kW at 660...690 V AC 50/60 Hz100 kW at 1000 V AC 50/60 Hz55 kW at 220...230 V AC 50/60 Hz
motor power HP (UL / CSA)
50 hp at 200 V AC60 hp at 230 V AC125 hp at 460 V AC150 hp at 575 V AC
JIS C8201-4-1IEC 60947-1IEC 60947-4-1EN 60947-1EN 60947-4-1
Product Certifications
RMRoSDNVLROS (Lloyds register of shipping)CSABVABSULCBRINA
Hold-in power consumption in VA
55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))66 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
IP degree of protection
IP2X front face with shrouds IEC 60529IP2X front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23...131 °F (-5...55 °C)
Ambient Air Temperature for Storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
-40...158 °F (-40...70 °C)
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 HzShocks contactor closed15 Gn for 11 msVibrations contactor closed5 Gn, 5...300 HzShocks contactor open7 Gn for 11 ms
Height
12.008 in (305 mm)
Width
6.6 in (168.5 mm)
Depth
7.1 in (181 mm)
Operating altitude
9842.52 ft (3000 m) without derating
LC1F185F722L TeSys F Nonreversing Contactor by Schneider Electric | INDPRT