Search manufacturers, products
Home
Manufacturers
Request Quote
Support
Shipping & Delivery
Refund & Return
Purchase Guide
About Us
Contact Us
Schneider Electric TeSys F LC1F1504U7 4-Pole AC-1 Contactor | INDPRT
Home
Schneider
Industrial Automation and Control
Contactors and Protection Relays
LC1F1504U7
Schneider
Contactors and Protection Relays
LC1F1504U7
Product Model
LC1F1504U7
Product ID
33090
Stock on Request
Last updated: 8/29/2026
Quantity
−
+
Add to RFQ
Request Quote Now
Key Features
1
Feature
-
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz<= 460 V DC
[Uc] control circuit voltage
240 V AC 40...400 Hz
[Ie] rated operational current
250 A (at <104 °F (40 °C)) at <= 440 V AC-1
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
250 A (at 104 °F (40 °C))
Rated breaking capacity
1200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
1200 A 104 °F (40 °C) - 10 s700 A 104 °F (40 °C) - 30 s600 A 104 °F (40 °C) - 1 min450 A 104 °F (40 °C) - 3 min350 A 104 °F (40 °C) - 10 min
Associated fuse rating
160 A aM at <= 440 V250 A gG at <= 440 V
Average impedance
0.35 mOhm - Ith 250 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole
22 W AC-1
Overvoltage category
III
power pole contact composition
4 NO
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))Drop-out 0.2...0.55 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability
10 Mcycles
Inrush power in VA
770 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA
8.1 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Operating time
35 ms closing at Uc) 130 ms opening at Uc)
Connections - terminals
Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable endControl circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable endControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable endControl circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable endControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable endControl circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable endPower circuit bar 2 25 x 3 mmPower circuit lugs-ring terminals 1 0.2 in² (120 mm²)Power circuit connector 1 0.2 in² (120 mm²)Power circuit bolted connection
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)Power circuit 159.3 lbf.in (18 N.m)
Mounting Support
Plate
Heat dissipation
5.9...7.2 W
Standards
EN 60947-1IEC 60947-1IEC 60947-4-1EN 60947-4-1JIS C8201-4-1
Product Certifications
DNVRINACBABSCCCBVULLROS (Lloyds register of shipping)RMRoSUKCA
compatibility code
LC1F
Control circuit type
AC 40...400 Hz
IP degree of protection
IP2X front face with shrouds IEC 60529IP2X front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
-40...140 °F (-40...60 °C)
Ambient Air Temperature for Storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
140...158 °F (60...70 °C) at Uc
Height
6.7 in (170 mm)
Width
7.9 in (200.5 mm)
Depth
6.7 in (171 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
8.44 lb(US) (3.83 kg)