The LC1F1504G6 TeSys F Contactor is designed for motor applications up to 75kW@400V, featuring a 120V 60Hz AC coil and bolt terminals for bars or cables.
Product ModelLC1F1504G6
Product ID33046
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureHigh-performance motor control for applications up to 75kW@400V.
2
Feature120V 60Hz AC coil for reliable operation.
3
FeatureBolt terminals for easy connection to bars or cables.
4
Feature2-year warranty for peace of mind.
5
FeatureSame-day shipping for quick delivery.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage
120 V AC 60 Hz
[Ie] rated operational current
250 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
250 A (at 104 °F (40 °C))
Rated breaking capacity
1200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
1200 A 104 °F (40 °C) - 10 s700 A 104 °F (40 °C) - 30 s600 A 104 °F (40 °C) - 1 min450 A 104 °F (40 °C) - 3 min350 A 104 °F (40 °C) - 10 min
Associated fuse rating
160 A aM at <= 440 V250 A gG at <= 440 V
Average impedance
0.35 mOhm - Ith 250 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole
22 W AC-1
Overvoltage category
III
power pole contact composition
4 NO
motor power HP (UL / CSA)
40 hp at 200 V AC50 hp at 230 V AC100 hp at 460 V AC125 hp at 575 V AC
EN 60947-4-1IEC 60947-1EN 60947-1IEC 60947-4-1JIS C8201-4-1
Product Certifications
DNVCBLROS (Lloyds register of shipping)RMRoSABSULRINACCCBV
Hold-in power consumption in VA
55 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
IP degree of protection
IP2X front face with shrouds IEC 60529IP2X front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
-40...140 °F (-40...60 °C)
Ambient Air Temperature for Storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
140...158 °F (60...70 °C)
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed6 Gn, 5...300 HzShocks contactor open9 Gn for 11 msShocks contactor closed15 Gn for 11 ms