High-power contactor for efficient power distribution in industrial applications.
Product ModelLC1F115Q522L
Product ID33017
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureEfficient power distribution for industrial applications
2
FeatureRobust performance and reliable operation
3
FeatureIdeal for high-power electrical systems
4
FeatureCompliant with international standards (e.g., IEC 60947-4-1)
5
FeatureEasy installation and maintenance
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive loadMotor control
Utilisation category
AC-4AC-1AC-3
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage
380 V AC 50 Hz
[Ie] rated operational current
200 A (at <104 °F (40 °C)) at <= 440 V AC AC-1115 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
200 A (at 104 °F (40 °C))
Rated breaking capacity
920 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
1100 A 104 °F (40 °C) - 10 s640 A 104 °F (40 °C) - 30 s520 A 104 °F (40 °C) - 1 min400 A 104 °F (40 °C) - 3 min320 A 104 °F (40 °C) - 10 min
Associated fuse rating
125 A aM at <= 440 V200 A gG at <= 440 V
Average impedance
0.37 mOhm - Ith 200 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole
15 W AC-15 W AC-3
Overvoltage category
III
power pole contact composition
3 NO
Auxiliary contact composition
2 NO + 2 NC
Motor power kW
55 kW at 380...400 V AC 50/60 Hz (AC-3)59 kW at 415 V AC 50/60 Hz (AC-3)59 kW at 440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660...690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3)30 kW at 220...230 V AC 50/60 Hz (AC-3)18.5 kW at 400 V AC 50/60 Hz (AC-4)
motor power HP (UL / CSA)
30 hp at 200 V AC40 hp at 230 V AC75 hp at 460 V AC100 hp at 575 V AC
JIS C8201-4-1EN 60947-1IEC 60947-4-1IEC 60947-1EN 60947-4-1
Product Certifications
CCCCBABSRINADNVRMRoSULLROS (Lloyds register of shipping)BV
Hold-in power consumption in VA
45 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
IP degree of protection
IP2X front face with shrouds IEC 60529IP2X front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
-40...140 °F (-40...60 °C)
Ambient Air Temperature for Storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
140...158 °F (60...70 °C) at Uc
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed6 Gn, 5...300 HzShocks contactor open9 Gn for 11 msShocks contactor closed15 Gn for 11 ms