Sensorless flux vector controlVoltage/frequency ratio (V/f)Quadratic voltage/frequency ratio
Maximum output frequency
4 kHz
Transient overtorque
150...170 % of nominal motor torque depending on drive rating and type of motor
Acceleration and deceleration ramps
SULinear from 0 to 999.9 s
Motor slip compensation
Preset in factoryAdjustable
Switching frequency
2...16 kHz adjustable4...16 kHz with derating factor
Nominal switching frequency
4 kHz
Braking to standstill
By DC injection
Brake chopper integrated
False
Line current
19.0 A 100 V heavy duty)15.9 A 120 V heavy duty)
Maximum Input Current per Phase
15.9 A
Maximum output voltage
240 V
Apparent power
6.6 kVA 240 V heavy duty)
Maximum transient current
18.3 A 60 s heavy duty)20.1 A 2 s heavy duty)
Network Frequency
50-60 Hz
Relative symmetric network frequency tolerance
5 %
Prospective line Isc
5 kA
Base load current at high overload
12.2 A
Power dissipation in W
Natural 94.0 W
With safety function Safely Limited Speed (SLS)
False
With safety function Safe brake management (SBC/SBT)
False
With safety function Safe Operating Stop (SOS)
False
With safety function Safe Position (SP)
False
With safety function Safe programmable logic
False
With safety function Safe Speed Monitor (SSM)
False
With safety function Safe Stop 1 (SS1)
False
With sft fct Safe Stop 2 (SS2)
False
With safety function Safe torque off (STO)
False
With safety function Safely Limited Position (SLP)
False
With safety function Safe Direction (SDI)
False
Protection type
Line supply overvoltageLine supply undervoltageOvercurrent between output phases and earthOverheating protectionShort-circuit between motor phasesAgainst input phase loss in three-phaseThermal motor protection via the drive by continuous calculation of I²t
Tightening torque
10.6 lbf.in (1.2 N.m)
Insulation
Electrical between power and control
Quantity per Set
Set of 1
Width
5.5 in (140 mm)
Height
7.2 in (184 mm)
Depth
3.9 in (100.2 mm)
Net Weight
3.5 lb(US) (1.6 kg)
Operating altitude
<= 3280.84 ft (1000 m) without derating> 3280.84...9842.52 ft (> 1000...3000 m) with current derating 1 % per 100 m
Operating position
Vertical +/- 10 degree
Product Certifications
NOMCSAC-tickULGOSTRCMKC
marking
CE
Standards
UL 508CUL 618000-5-1IEC 61800-5-1IEC 61800-3
Assembly style
On base plate
Electromagnetic compatibility
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4Electrostatic discharge immunity test level 3 IEC 61000-4-2Immunity to conducted disturbances level 3 IEC 61000-4-6Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3Surge immunity test level 3 IEC 61000-4-5Voltage dips and interruptions immunity test IEC 61000-4-11
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)
10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)