Schneider Electric's LC1D40004Q5 contactor is designed for industrial automation, offering reliable performance and efficient operation.
Product ModelLC1D40004Q5
Product ID32123
Stock on Request
Last updated: 8/29/2026
Key Features
1
Reliable PerformanceThe LC1D40004Q5 contactor from Schneider Electric ensures consistent and reliable performance in industrial automation applications.
2
Efficient OperationWith its efficient operation, the LC1D40004Q5 contactor minimizes energy consumption and maximizes productivity in your industrial setup.
3
Durable DesignBuilt with a durable design, the LC1D40004Q5 contactor withstands harsh industrial environments, ensuring long-lasting performance.
4
Easy InstallationThe LC1D40004Q5 contactor features easy installation, reducing downtime and making it simpler to integrate into your existing automation systems.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC-1AC-3AC-3eAC-4
Poles description
4P
High Current RatingCapable of handling 60A, the LC1D40004Q5 contactor is suitable for a wide range of industrial applications requiring high current ratings.
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current
60 A (at <140 °F (60 °C)) AC AC-1 for power circuit
[Uc] control circuit voltage
380 V AC 50 Hz
compatibility code
LC1D
Pole contact composition
4 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for control circuit60 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
140 A AC for control circuit conforming to IEC 60947-5-1800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
800 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-180 A gG at <= 690 V coordination type 1 for power circuit80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole
5.4 W AC-1
[Ui] rated insulation voltage
Control circuit 600 V CSAControl circuit 600 V ULPower circuit 600 V CSAPower circuit 600 V ULControl circuit 690 V IEC 60947-1Power circuit 690 V IEC 60947-1
Overvoltage category
III
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
6000000 cycles
Control circuit type
AC 50 Hz standard
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.3...0.6 Uc 140 °F (60 °C) drop-out AC 50 Hz0.85...1.1 Uc 131 °F (55 °C) operational AC 50 Hz
Inrush power in VA
140 VA cos phi 0.75 (at 68 °F (20 °C))160 VA cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA
13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))