The LC1D40004F7 is a 4-pole IEC contactor designed for nonreversing applications, offering 60A resistive power.
Product ModelLC1D40004F7
Product ID32115
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureHigh reliability and efficiency in electrical control systems.
2
FeatureDesigned for nonreversing applications with 60A resistive power.
3
FeatureCompact and versatile, suitable for DIN rail or panel mounting.
4
FeatureIdeal for use in industrial automation and control systems.
5
FeatureCompliant with IEC standards for safety and performance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC-1AC-3AC-3eAC-4
Poles description
4P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current
60 A (at <140 °F (60 °C)) AC AC-1 for power circuit
[Uc] control circuit voltage
110 V AC 50/60 Hz
compatibility code
LC1D
Pole contact composition
4 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for control circuit60 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
140 A AC for control circuit conforming to IEC 60947-5-1800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
800 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-180 A gG at <= 690 V coordination type 1 for power circuit80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole
5.4 W AC-1
[Ui] rated insulation voltage
Control circuit 600 V CSAControl circuit 600 V ULPower circuit 600 V CSAPower circuit 600 V ULControl circuit 690 V IEC 60947-1Power circuit 690 V IEC 60947-1
Overvoltage category
III
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
6000000 cycles
Control circuit type
AC 50/60 Hz standard
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.3...0.6 Uc 140 °F (60 °C) drop-out AC 50/60 Hz0.8...1.1 Uc 140 °F (60 °C) operational AC 50 Hz0.85...1.1 Uc 140 °F (60 °C) operational AC 60 Hz
Inrush power in VA
140 VA cos phi 0.75 (at 68 °F (20 °C))160 VA cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA
13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
1.5 ms on de-energisation between NC and NO contacts1.5 ms on energisation between NC and NO contacts
Mounting Support
PlateRail
Standards
EN 60947-4-1UL 508EN 60947-5-1CSA C22.2 No 14IEC 60947-5-1IEC 60947-4-1
Product Certifications
DNVGOSTRINACSAULLROS (Lloyds register of shipping)CCCBVGLUKCA
IP degree of protection
IP2X IEC 60529IP2X VDE 0106
Protective treatment
TH 3)IEC 60068
Permissible ambient air temperature around the device
23...140 °F (-5...60 °C)-40...158 °F (-40...70 °C) at Uc
Operating altitude
9842.52 ft (3000 m) without derating
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Shocks contactor open 8 Gn for 11 ms) Shocks contactor closed 10 Gn for 11 ms) Vibrations contactor opened 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz)