Schneider Electric LC1D32JD IEC Contactor for motor control applications with 12VDC coil and 3NO contact configuration.
Product ModelLC1D32JD
Product ID31828
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureDesigned for motor control applications with a 12VDC coil.
2
FeatureIdeal for 20HP at 480VAC and up to 100kA SCCR.
3
FeatureEnhance your control systems with TeSys D's efficiency and reliability.
4
FeaturePerfect integration in control systems with screw clamp terminals.
5
FeatureSimplified maintenance with 90% less references needed.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive loadMotor control
Utilisation category
AC-1AC-3AC-4AC-3e
Poles description
3P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC
[Ie] rated operational current
32 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit50 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit32 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
12 V DC
Motor power kW
7.5 kW at 220...230 V AC 50/60 Hz (AC-3)15 kW at 380...400 V AC 50/60 Hz (AC-3)15 kW at 415...440 V AC 50/60 Hz (AC-3)18.5 kW at 500 V AC 50/60 Hz (AC-3)18.5 kW at 660...690 V AC 50/60 Hz (AC-3)7.5 kW at 400 V AC 50/60 Hz (AC-4)7.5 kW at 220...230 V AC 50/60 Hz (AC-3e)15 kW at 380...400 V AC 50/60 Hz (AC-3e)15 kW at 415...440 V AC 50/60 Hz (AC-3e)18.5 kW at 500 V AC 50/60 Hz (AC-3e)18.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating
2 hp at 115 V AC 50/60 Hz for 1 phase motors5 hp at 230/240 V AC 50/60 Hz for 1 phase motors10 hp at 200/208 V AC 50/60 Hz for 3 phase motors10 hp at 230/240 V AC 50/60 Hz for 3 phase motors20 hp at 460/480 V AC 50/60 Hz for 3 phase motors25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
compatibility code
LC1D
Pole contact composition
3 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for signalling circuit50 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1550 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
550 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
260 A 104 °F (40 °C) - 10 s for power circuit430 A 104 °F (40 °C) - 1 s for power circuit60 A 104 °F (40 °C) - 10 min for power circuit138 A 104 °F (40 °C) - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
Associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-163 A gG at <= 690 V coordination type 1 for power circuit63 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
2 mOhm - Ith 50 A 50 Hz for power circuit
Power dissipation per pole
2 W AC-35 W AC-12 W AC-3e
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V UL
Overvoltage category
III
Pollution degree
3
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
30 Mcycles
Electrical durability
1.65 Mcycles 32 A AC-3 <= 440 V1.4 Mcycles 50 A AC-1 <= 440 V1.65 Mcycles 32 A AC-3e <= 440 V
1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact
Mounting Support
RailPlate
Standards
CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 60947-4-1IEC 60335-1:Clause 30.2IEC 60335-2-40:Annex JJUL 60335-2-40:Annex JJCSA C22.2 No 60947-4-1
Product Certifications
ULCCCCSAMarineUKCAEACCB Scheme
IP degree of protection
IP20 front face IEC 60529
Protective treatment
THIEC 60068-2-30
Climatic withstand
IACS E10 exposure to damp heat IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device
-40...140 °F (-40...60 °C)140...158 °F (60...70 °C) with derating
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz) Shocks contactor closed 15 Gn for 11 ms) Shocks contactor open 8 Gn for 11 ms)
Height
3.3 in (85 mm)
Width
1.8 in (45 mm)
Depth
4.0 in (101 mm)
Net Weight
1.179 lb(US) (0.535 kg)
Schneider Electric LC1D32JD IEC Contactor | Augto.com | INDPRT