Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
Altivar Soft Starter ATS480
Product or Component Type
Soft starter
Product destination
Asynchronous motors
Product Specific Application
Process and infrastructures
Device short name
ATS480
Phase
3 phase
Utilisation category
AC-3AAC-53A
Ue power supply voltage
208...690 V - 15...10 %
power supply frequency
50...60 Hz - 20...20 %
[Ie] rated operational current
Normal duty 38.0 A 104 °F (40 °C))
rated current in heavy duty
32.0 A at 104 °F (40 °C) heavy duty
Torque control
True
IP Degree of Protection
IP20
Motor power kW
9.0 kW 230 V in the motor supply line normal duty7.5 kW 230 V in the motor supply line heavy duty18.5 kW 400 V in the motor supply line normal duty15.0 kW 400 V in the motor supply line heavy duty18.5 kW 440 V in the motor supply line normal duty15.0 kW 440 V in the motor supply line heavy duty22.0 kW 500 V in the motor supply line normal duty18.5 kW 500 V in the motor supply line heavy duty22.0 kW 525 V in the motor supply line normal duty18.5 kW 525 V in the motor supply line heavy duty30.0 kW 660 V in the motor supply line normal duty22.0 kW 660 V in the motor supply line heavy duty30.0 kW 690 V in the motor supply line normal duty22.0 kW 690 V in the motor supply line heavy duty18.5 kW 230 V to the motor delta terminals normal duty15.0 kW 230 V to the motor delta terminals heavy duty30.0 kW 400 V to the motor delta terminals normal duty22.0 kW 400 V to the motor delta terminals heavy duty
Maximum Horse Power Rating
10.0 hp 208 V normal duty7.5 hp 208 V heavy duty10.0 hp 230 V heavy duty25.0 hp 460 V normal duty20.0 hp 460 V heavy duty30.0 hp 575 V normal duty25.0 hp 575 V heavy duty
Option card
Communication module Profibus DP V1Communication module Modbus TCP/EtherNet/IPCommunication module CANopen daisy chainCommunication module CANopen Sub-DCommunication module CANopen open style
Device connection
In the motor supply lineTo the motor delta terminals
[Us] control circuit voltage
110...230 V AC 50/60 Hz - 15...10 %
Apparent power
0.09 kVA
Integrated motor overload protection
True
motor thermal protection class
Class 10E
Protection type
Phase failure lineIntegrated thermal protection motorThermal protection starterCurrent overload motorUnderload motorExcessive starting time, locked rotor motorMotor phase loss motorLine supply phase loss lineLine supply phase loss motorThermal protection motor