The ATS480C79Y soft starter by Schneider Electric is designed for process and infrastructure applications, offering robust cybersecurity features and a wide power range.
Product ModelATS480C79Y
Product ID31325
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureOptimized for digitization and cybersecurity standards.
2
FeatureWide power range from 3 to 900 kW, suitable for various applications.
3
FeatureRobust design for demanding environments, ensuring high availability.
4
FeatureEasy project execution with simplified setup and configuration.
5
FeatureReuses current design, preserving initial investment and extending equipment lifetime.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
Altivar Soft Starter ATS480
Product or Component Type
Soft starter
Product destination
Asynchronous motors
Product Specific Application
Process and infrastructures
Device short name
ATS480
Phase
3 phase
Utilisation category
AC-3AAC-53A
Ue power supply voltage
208...690 V - 15...10 %
power supply frequency
50...60 Hz - 20...20 %
[Ie] rated operational current
Normal duty 790.0 A 104 °F (40 °C))
rated current in heavy duty
660.0 A at 104 °F (40 °C) heavy duty
Torque control
True
IP Degree of Protection
IP00
Motor power kW
220.0 kW 230 V in the motor supply line normal duty400.0 kW 400 V in the motor supply line normal duty355.0 kW 400 V in the motor supply line heavy duty500.0 kW 440 V in the motor supply line normal duty400.0 kW 440 V in the motor supply line heavy duty500.0 kW 500 V in the motor supply line normal duty500.0 kW 525 V in the motor supply line normal duty710.0 kW 660 V in the motor supply line normal duty630.0 kW 660 V in the motor supply line heavy duty710.0 kW 690 V in the motor supply line normal duty630.0 kW 690 V in the motor supply line heavy duty355.0 kW 230 V to the motor delta terminals normal duty315.0 kW 230 V to the motor delta terminals heavy duty630.0 kW 400 V to the motor delta terminals normal duty500.0 kW 400 V to the motor delta terminals heavy duty
Maximum Horse Power Rating
250.0 hp 208 V normal duty200.0 hp 208 V heavy duty300.0 hp 230 V normal duty250.0 hp 230 V heavy duty600.0 hp 460 V normal duty500.0 hp 460 V heavy duty800.0 hp 575 V normal duty600.0 hp 575 V heavy duty
Option card
Communication module Profibus DP V1Communication module Modbus TCP/EtherNet/IPCommunication module CANopen daisy chainCommunication module CANopen Sub-DCommunication module CANopen open style
Device connection
In the motor supply lineTo the motor delta terminals
[Us] control circuit voltage
110...230 V AC 50/60 Hz - 15...10 %
Apparent power
0.2 kVA
Integrated motor overload protection
True
motor thermal protection class
Class 10E
Protection type
Phase failure lineIntegrated thermal protection motorThermal protection starterCurrent overload motorUnderload motorExcessive starting time, locked rotor motorMotor phase loss motorLine supply phase loss lineLine supply phase loss motorThermal protection motor