Schneider Electric GV2LE10 TeSys GV2 Circuit Breaker: Magnetic protection for 3-phase motor applications with 6.3A current rating and 690V voltage rating.
Product ModelGV2LE10
Product ID30183
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureMagnetic Protection
2
FeatureHigh Current Rating
3
FeatureScrew Clamp Terminals
4
Feature3-Phase Motor Compatibility
5
FeatureDurable Construction
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range
TeSys Deca
Product name
TeSys GV2
Product or Component Type
Motor circuit breaker
Device short name
GV2LE
Device Application
Motor protection
Trip unit technology
Magnetic
Poles description
3P
Network type
AC
Utilisation category
Category A IEC 60947-2AC-3 IEC 60947-4-1AC-3e IEC 60947-4-1
Network frequency
50/60 Hz IEC 60947-2
Motor power kW
2.2 kW 400/415 V AC 50/60 Hz3 kW 500 V AC 50/60 Hz4 kW 690 V AC 50/60 Hz
Breaking capacity
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-250 kA Icu 440 V AC 50/60 Hz IEC 60947-250 kA Icu 500 V AC 50/60 Hz IEC 60947-23 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity
100 % 230/240 V AC 50/60 Hz IEC 60947-2100 % 400/415 V AC 50/60 Hz IEC 60947-2100 % 440 V AC 50/60 Hz IEC 60947-2100 % 500 V AC 50/60 Hz IEC 60947-275 % 690 V AC 50/60 Hz IEC 60947-2
Control Type
Toggle
Line Rated Current
6.3 A
Thermal protection adjustment range
2.5...4 A IEC 60947-4-1
Magnetic tripping current
91 A
[Ith] conventional free air thermal current
6.3 A IEC 60947-4-1
[Ue] rated operational voltage
690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage
690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-2
Suitability for isolation
Yes IEC 60947-1
Power dissipation per pole
1.8 W
Mechanical durability
100000 cycles
Electrical durability
100000 cycles AC-3 415 V In100000 cycles AC-3e 415 V In
Rated duty
Continuous IEC 60947-4-1
Tightening torque
15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode
35 mm symmetrical DIN rail clippedPanel screwed with adaptor plate)
Mounting position
HorizontalVertical
Width
1.8 in (45 mm)
Height
3.5 in (89 mm)
Depth
3.09 in (78.5 mm)
Net Weight
0.73 lb(US) (0.33 kg)
color
Dark grey
Standards
EN/IEC 60947-2EN/IEC 60947-4-1UL 60947-4-1CSA C22.2 No 60947-4-1IEC/EN 60335-2-40:Annex JJ
Product Certifications
CCCULCSAEACLROS (Lloyds register of shipping)BVRINADNV-GLUKCAIECEE CB Scheme
IK degree of protection
IK04
IP degree of protection
IP20 IEC 60529
Climatic withstand
IACS E10
Ambient Air Temperature for Storage
-40...176 °F (-40...80 °C)
Fire resistance
1760 °F (960 °C) IEC 60695-2-11
Ambient air temperature for operation
-4...140 °F (-20...60 °C)
Mechanical robustness
Shocks 30 Gn for 11 msVibrations 5 Gn, 5...150 Hz
Operating altitude
6561.68 ft (2000 m)
Schneider Electric GV2LE10 TeSys GV2 Circuit Breaker | INDSLT