Schneider Electric GV2L04 TeSys Deca Manual Starter and Protector for 3-phase motor applications with magnetic protection.
Product ModelGV2L04
Product ID30166
Stock on Request
Last updated: 8/29/2026
Key Features
1
Reliable ProtectionThe GV2L04 offers reliable magnetic protection for your 3-phase motor applications, ensuring safe operation and minimizing downtime.
2
Easy InstallationWith its simple rotary handle and screw clamp terminals, the GV2L04 is easy to install and maintain, saving you time and effort.
3
Versatile UseSuitable for a wide range of motor applications from 0.12 to 0.18 kW, the GV2L04 is a versatile solution for various industrial needs.
4
High-Quality ComponentsBuilt with high-quality components, the GV2L04 ensures durability and long-lasting performance in demanding environments.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range
TeSys Deca
Product name
TeSys GV2
Product or Component Type
Motor circuit breaker
Device short name
GV2L
Device Application
Motor protection
Trip unit technology
Magnetic
Compliance with StandardsThe GV2L04 meets all relevant industry standards, providing peace of mind and ensuring compliance with regulatory requirements.
Poles description
3P
Network type
AC
Utilisation category
Category A IEC 60947-2AC-3 IEC 60947-4-1AC-3e IEC 60947-4-1
Network frequency
50/60 Hz IEC 60947-2
Motor power kW
0.12 kW 400/415 V AC 50/60 Hz0.18 kW 400/415 V AC 50/60 Hz0.37 kW 690 V AC 50/60 Hz
Breaking capacity
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2100 kA Icu 440 V AC 50/60 Hz IEC 60947-2100 kA Icu 500 V AC 50/60 Hz IEC 60947-2100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity
100 % 230/240 V AC 50/60 Hz IEC 60947-2100 % 400/415 V AC 50/60 Hz IEC 60947-2100 % 440 V AC 50/60 Hz IEC 60947-2100 % 500 V AC 50/60 Hz IEC 60947-2100 % 690 V AC 50/60 Hz IEC 60947-2
Control Type
Rotary handle
Line Rated Current
0.63 A
Thermal protection adjustment range
0.4...0.63 A IEC 60947-4-1
Magnetic tripping current
9.3 A
[Ith] conventional free air thermal current
0.63 A IEC 60947-4-1
[Ue] rated operational voltage
690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage
690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-2
Suitability for isolation
Yes IEC 60947-1
Power dissipation per pole
1.8 W
Mechanical durability
100000 cycles
Electrical durability
100000 cycles AC-3 415 V In100000 cycles AC-3e 415 V In
Rated duty
Continuous IEC 60947-4-1
Tightening torque
15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode
35 mm symmetrical DIN rail clippedPanel screwed with 2 x M4 screws)
Mounting position
HorizontalVertical
Width
1.8 in (45 mm)
Height
3.5 in (89 mm)
Depth
3.8 in (97 mm)
Net Weight
0.73 lb(US) (0.33 kg)
color
Dark grey
Standards
EN/IEC 60947-2EN/IEC 60947-4-1UL 60947-4-1CSA C22.2 No 60947-4-1IEC/EN 60335-2-40:Annex JJ
Product Certifications
CCCULCSAEACLROS (Lloyds register of shipping)BVRINADNV-GLUKCAIECEE CB Scheme
IK degree of protection
IK04
IP degree of protection
IP20 IEC 60529
Climatic withstand
IACS E10
Ambient Air Temperature for Storage
-40...176 °F (-40...80 °C)
Fire resistance
1760 °F (960 °C) IEC 60695-2-11
Ambient air temperature for operation
-4...140 °F (-20...60 °C)
Mechanical robustness
Shocks 30 Gn for 11 msVibrations 5 Gn, 5...150 Hz
Operating altitude
6561.68 ft (2000 m)
Schneider Electric GV2L04 TeSys Deca Manual Starter and Protector | INDSLT