+/-0.5 mm 10...55 Hz)IEC 60068-2-66 gn 55...150 Hz)IEC 60068-2-6
Shock resistance
25 gn 6 ms) 6000 shocks IEC 60068-2-2715 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Insulation resistance
> 500 MOhm 500 V DC NF C 20030
[Ui] rated insulation voltage
250 V IEC 60664-1
Electromagnetic compatibility
Immunity for industrial environments conforming to IEC 61000-6-2Conducted and radiated emissions class B conforming to CISPR 22Electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2Electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2Susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz) conforming to IEC 61000-4-3Susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m) conforming to IEC 61000-4-3Electrical fast transient/burst immunity test - test level: 2 kV conforming to IEC 61000-4-41.2/50 µs shock waves immunity test - test level: 1 kV (differential mode) conforming to IEC 61000-4-51.2/50 µs shock waves immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5Conducted RF disturbances - test level: 10 V conforming to IEC 61000-4-6Immunity to microbreaks and voltage drops conforming to IEC 61000-4-11Radiated emission conforming to ETSI EN 300 440-1Conducted emission conforming to EN 300-489-1Conducted emission conforming to ETSI EN 300 489-3Radiated emission conforming to ETSI EN 300 440-2
Wireless and Batteryless Harmony XB5R Relay Antenna | INDPRT