The ZB6ZH01B is a versatile contact and light block designed for robust applications, offering IP65 protection and compliance with major certifications.
Product Model
ZB6ZH01B
Product ID28164
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureCompact design for restricted surface areas
2
FeatureCompliant with IEC, UL, CSA, and CCC standards
3
FeatureIdeal for industrial and commercial applications
4
FeatureEnhanced reliability with IP65 protection
5
FeatureVersatile connections via quick connectors or solder tabs
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range of Product
Harmony XB6
Product or Component Type
Complete body for illuminated push-button
Device short name
ZB6
Fixing collar material
Plastic
Sale per indivisible quantity
1
Contacts type and composition
1 NO
Contact operation
Slow-break
Connections - terminals
Faston connector 2.8 x 0.5 mm
Light source
Incandescent (bulb not included)
Bulb base
BA 9s
Light block supply
Direct
[Us] rated supply voltage
3...24 V
CAD overall width
0.9 in (24 mm)
CAD overall height
0.7 in (18 mm)
CAD overall depth
1.6 in (40 mm)
Terminals description ISO n°1
(13-14)NO
Net Weight
0.013 lb(US) (0.006 kg)
Contacts usage
Standard
Positive opening
With EN/IEC 60947-5-1 appendix K
Operating travel
0.08 in (2 mm) NO changing electrical state)0.2 in (4.3 mm) total travel)
Operating force
1.6 N NO changing electrical state
Contacts material
Silver alloy (Ag/Ni)
Short-circuit protection
6 A cartridge fuse gG EN/IEC 60947-5-1
[Ui] rated insulation voltage
250 V 3)EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
4 kV EN/IEC 60947-1
[Ie] rated operational current
3 A 120 V, AC-15, B3001.5 A 240 V, AC-15, B3000.1 A 250 V, DC-13, R3000.22 A 125 V, DC-13, R300
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C1000000 cycles, DC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical reliability
Î = 10exp(-8) 5 V 1 mA with confidence level of 90 % EN/IEC 60947-5-4
Signalling type
Steady
current consumption
15 mA
Surge withstand
1 kV direct contact IEC 61000-4-52 kV in free air IEC 61000-4-5
Protective treatment
TC
Ambient Air Temperature for Storage
-40...158 °F (-40...70 °C)
Ambient Air Temperature for Operation
-13...158 °F (-25...70 °C)
Electrical shock protection class
Class II IEC 61140
Standards
EN/IEC 60947-1EN/IEC 60947-5-1JIS C 4520JIS C 852EN/IEC 60947-5-5UL 508CSA C22.2 No 14
Product Certifications
CSACCCULGOST
Vibration resistance
+/- 3 mm 2...500 Hz)IEC 60068-2-65 gn 2...500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-2750 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Resistance to fast transients
2 kV IEC 61000-4-4
Resistance to electromagnetic fields
9.1 V/m (10 V/m) IEC 61000-4-3
Resistance to electrostatic discharge
6 kV on contact (on metal parts) IEC 61000-2-68 kV in free air (in insulating parts) IEC 61000-2-6