Reliable OperationThe Festo VSNC-F-P53U-MH-G14-F19 is designed for reliable operation, ensuring consistent performance in various industrial applications. Its mechanical spring reset method ensures stable valve function.
2
Soft Sealing PrincipleEquipped with a soft sealing principle, this valve provides efficient and leak-free operation. The NBR seals ensure high durability and resistance to wear.
3
Pilot-Controlled OperationThe valve is pilot-controlled, allowing for precise control over the flow of compressed air. This feature is particularly useful in applications requiring high accuracy and flexibility.
4
Compliance with StandardsThe VSNC-F-P53U-MH-G14-F19 conforms to the VDI/VDE 3845 standard, ensuring compatibility with a wide range of industrial systems. This compliance guarantees seamless integration into existing setups.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Valve function
5/3, pressurized
Actuation type
Electrical
Width
32mm
Standard nominal flow rate
950l/min
Pneumatic working port
NAMUR connection diagram
Operating voltage
Via solenoid coil, to be ordered separately
5
Durable ConstructionConstructed from high-quality materials, including wrought aluminum alloy and high-alloy stainless steel screws, this valve is built to withstand moderate corrosion stress. Its robust design ensures long-lasting performance in various environments.
Operating pressure
3bar 8bar
Structural design
Piston gate valve
Reset method
Mechanical spring
Exhaust air function
With flow control option
Sealing principle
Soft
Mounting position
Any
Conforms to standard
VDI/VDE 3845 (NAMUR)
Manual override
Non-detenting
Type of control
Pilot-controlled
Pilot air supply port
Internal
Flow direction
Non-reversible
Symbol
00991083
Lap
Overlap
b-value
0.5
C value
2.1l/sbar
Switching time off
85ms
On switching time
24ms
Changeover time
60ms
Duty cycle
100%
Coil characteristics
See solenoid coil, to be ordered separately
Explosion prevention and protection
Observe the information on the certificate Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX)
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)