High Flow RateThe VUVS-LT30-T32H-MZD-G38-F8-1C1 offers a standard nominal flow rate of 1600 l/min, making it ideal for applications requiring high fluid flow.
2
Precise ControlWith its monostable design, this solenoid valve provides precise control over fluid flow, ensuring consistent performance in various industrial settings.
3
ReliabilityBuilt with a mechanical spring reset and soft sealing principle, the VUVS-LT30-T32H-MZD-G38-F8-1C1 ensures reliable operation and long service life.
4
Versatile Mounting OptionsThe valve can be mounted either on a manifold rail or with a through-hole, offering flexibility in installation and integration into different systems.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Valve function
2x3/2, open/closed, monostable
Actuation type
Electrical
Valve size
31mm
Standard nominal flow rate
1600l/min
Pneumatic working port
G3/8
Operating voltage
24V DC
Compliance and CertificationThe Festo VUVS-LT30-T32H-MZD-G38-F8-1C1 meets stringent standards, including cULus recognition and compliance with ISO 8573-1:2010, making it suitable for a wide range of industrial applications.
Operating pressure
1bar 10bar
Structural design
Plate seat
Reset method
Mechanical spring
Certification
c UL us - Recognized (OL)
Degree of protection
IP65 With plug socket as per IEC 60529
Nominal width
7.8mm
Exhaust air function
With flow control option
Sealing principle
Soft
Mounting position
Any
Manual override
Detenting Non-detenting
Type of control
Pilot-controlled
Pilot air supply port
External
Flow direction
Non-reversible
Symbol
00995865
Lap
Underlap
Pilot pressure MPa
0.25MPa 1MPa
Pilot pressure
2.5bar 10bar
b-value
0.3
C value
6.7l/sbar
Switching time off
37ms
On switching time
13ms
Duty cycle
100%
Max. positive test pulse with 0 signal
2000μs
Max. negative test pulse on 1 signal
3600μs
Coil characteristics
24 V DC: 3.3 W
Permissible voltage fluctuations
+/- 10 %
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)
Vibration resistance
Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Shock resistance
Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27