Precision ControlThe VUVS-LT30-M32U-MD-G38-F8-1B2 offers precise control over air flow, ensuring accurate operation in various industrial applications.
2
ReliabilityDesigned with reliability in mind, this valve ensures consistent performance and minimizes downtime, making it a trusted choice for critical systems.
3
VersatilitySuitable for a wide range of pneumatic systems, the VUVS-LT30-M32U-MD-G38-F8-1B2 is adaptable to different industrial needs, from manufacturing to automation.
4
EfficiencyWith its efficient design, this valve optimizes air flow management, reducing energy consumption and enhancing overall system performance.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Valve function
3/2, open, monostable
Actuation type
Electrical
Valve size
31mm
Standard nominal flow rate
1600l/min
Pneumatic working port
G3/8
Operating voltage
24V DC
DurabilityConstructed with high-quality materials, the VUVS-LT30-M32U-MD-G38-F8-1B2 is built to last, providing long-lasting service and minimal maintenance requirements.
Operating pressure
2.5bar 10bar
Structural design
Plate seat
Reset method
Mechanical spring
Certification
c UL us - Recognized (OL)
Degree of protection
IP65 With plug socket as per IEC 60529
Nominal width
7.9mm
Exhaust air function
With flow control option
Sealing principle
Soft
Mounting position
Any
Manual override
Detenting Non-detenting
Type of control
Pilot-controlled
Pilot air supply port
Internal
Flow direction
Non-reversible
Symbol
00991140
Lap
Underlap
b-value
0.2
C value
7l/sbar
Switching time off
36ms
On switching time
14ms
Duty cycle
100%
Max. positive test pulse with 0 signal
2000μs
Max. negative test pulse on 1 signal
3600μs
Coil characteristics
24 V DC: 3.3 W
Permissible voltage fluctuations
+/- 10 %
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)
Vibration resistance
Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Shock resistance
Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27