Precise ControlThe Festo VUVS-L30-P53U-MZD-G38-F8-1C1 air solenoid valve offers a 5/3-way pressurized design, ensuring precise control over pneumatic systems.
2
Efficient OperationWith a standard nominal flow rate of 1600 l/min, this valve optimizes system performance and efficiency.
3
Electrical ActuationThe valve is electrically actuated, providing reliable and consistent operation with minimal maintenance.
4
Compact DesignThe 31 mm valve size makes it ideal for applications where space is limited, ensuring seamless integration into various systems.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Valve function
5/3, pressurized
Actuation type
Electrical
Valve size
31mm
Standard nominal flow rate
1600l/min
Pneumatic working port
G3/8
Operating voltage
24V DC
Pneumatic Working PortThe valve features a G3/8 pneumatic working port, accommodating a wide range of pneumatic connections and configurations.
Operating pressure
-0.9bar 10bar
Structural design
Piston gate valve
Reset method
Mechanical spring
Certification
c UL us - Recognized (OL)
Degree of protection
IP65 With plug socket as per IEC 60529
Nominal width
8.1mm
Exhaust air function
With flow control option
Sealing principle
Soft
Mounting position
Any
Manual override
Detenting Non-detenting
Type of control
Pilot-controlled
Pilot air supply port
External
Flow direction
Reversible
Symbol
00991031
Lap
Overlap
Pilot pressure MPa
0.25MPa 1MPa
Pilot pressure
2.5bar 10bar
b-value
0.4
C value
6.6l/sbar
Switching time off
75ms
On switching time
18ms
Changeover time
31ms
Duty cycle
100%
Max. positive test pulse with 0 signal
2000μs
Max. negative test pulse on 1 signal
3600μs
Coil characteristics
24 V DC: 3.3 W
Permissible voltage fluctuations
+/- 10 %
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)
Vibration resistance
Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Shock resistance
Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27