High Flow RateThe VUVG-L18-P53C-T-G14-1P3 solenoid valve boasts a standard nominal flow rate of 1200 l/min, making it suitable for high-demand applications.
2
Reliable Electrical ActuationWith a 24V DC operating voltage, this valve ensures consistent and reliable operation in your pneumatic system.
3
Compact DesignThe valve size is 18 mm, making it compact and easy to integrate into various pneumatic setups.
4
Pneumatic Working PortThe valve features a G1/4 pneumatic working port, providing flexibility in connecting to different pneumatic components.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Valve function
5/3, closed
Actuation type
Electrical
Valve size
18mm
Standard nominal flow rate
1200l/min
Pneumatic working port
G1/4
Operating voltage
24V DC
Versatile ApplicationThe 5/3 way function of the VUVG-L18-P53C-T-G14-1P3 solenoid valve makes it versatile for a wide range of pneumatic applications, from manufacturing to automation.
Operating pressure
3bar 8bar
Structural design
Piston gate valve
Reset method
Mechanical spring
Certification
RCM compliance mark c UL us - Recognized (OL)
Degree of protection
IP40 IP65 With plug socket
Nominal width
6.5mm
Exhaust air function
With flow control option
Sealing principle
Soft
Mounting position
Any
Manual override
Detenting Non-detenting Covered
Type of control
Pilot-controlled
Pilot air supply port
Internal
Symbol
00992896
Lap
Overlap
Pilot pressure MPa
0.3MPa 0.8MPa
Pilot pressure
3bar 8bar
Switching time off
48ms
On switching time
15ms
Changeover time
29ms
Duty cycle
100%
Max. positive test pulse with 0 signal
700μs
Max. negative test pulse on 1 signal
900μs
Coil characteristics
24 V DC: 1.0 W 24 V DC: low-current phase 0.3 W, high-current phase 1.0 W
Permissible voltage fluctuations
+/- 10 %
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)
Vibration resistance
Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Restricted ambient and media temperature
-5 - 50 °C Without holding power reduction
Shock resistance
Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27