Product Net Width
15 mm
Product Net Depth / Length
89.65 mm
Number of Auxiliary Contacts NC
2
Standards
IEC/EN 60941-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14
Rated Operational Voltage
Auxiliary Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I<sub>th</sub>)
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (I<sub>e</sub>)
(500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (380 / 400 V) 3 A
Short-Circuit Protective Devices
Auxiliary Circuit - gG Type Fuses 10 A
Rated Operational Current DC-13 (I<sub>e</sub>)
(24 V) 6 A (48 V) 2.8 A (72 V) 1 A (125 V) 0.55 A (250 V) 0.3 A
Rated Insulation Voltage (U<sub>i</sub>)
acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V
Mechanical Durability
5 million
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Terminal Type
Screw Terminals
Suitable For
AF45 AF50 AF63 AF75 AF95B A30 A40 A45 A50 A63 A75 A95 A110 AE45 AE50 AE63 AE75 TAE45 TAE50 TAE75 GA75 GAE75 AX32 AX40 AX50 AX65 AX80 AX95 AX115 AX150
ETIM 7
EC001044 - Mechanic interlock for switch
ETIM 8
EC001044 - Mechanic interlock for switch
ETIM 9
EC001044 - Mechanic interlock for switch
IDEA Granular Category Code (IGCC)
5219 >> Switch part or accessory
Manufacturer ID
1SBN030210R1000