The LC1F330 TeSys F Contactor is a reliable and efficient 3P(3NO) AC-3 contactor designed for motor applications up to 160kW@400V.
Product ModelLC1F330
Product ID111052
Stock on Request
Last updated: 8/29/2026
Key Features
1
Feature-
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Range
TeSys
Product name
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Motor controlResistive load
Utilisation category
AC-4AC-3AC-1
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
[Ie] rated operational current
400 A 104 °F (40 °C)) <= 440 V AC AC-1330 A 131 °F (55 °C)) <= 440 V AC AC-3
Motor power kW
160 kW at 1000 V AC 50/60 Hz (AC-3)160 kW at 380...400 V AC 50/60 Hz (AC-3)180 kW at 415 V AC 50/60 Hz (AC-3)200 kW at 440 V AC 50/60 Hz (AC-3)200 kW at 500 V AC 50/60 Hz (AC-3)100 kW at 220...240 V AC 50/60 Hz (AC-3)220 kW at 660...690 V AC 50/60 Hz (AC-3)59 kW at 400 V AC 50/60 Hz (AC-4)
[Uc] control circuit voltage
24...1000 V AC 40...400 Hz with LX1/LX9 coil24...460 V DC with LX4 coil100...250 V AC 50/60 Hz with LXE coil100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
400 A (at 104 °F (40 °C))
Irms rated making capacity
3300 A AC conforming to IEC 60947-4-1
Rated breaking capacity
2640 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
2650 A 104 °F (40 °C) - 10 s1800 A 104 °F (40 °C) - 30 s1300 A 104 °F (40 °C) - 1 min900 A 104 °F (40 °C) - 3 min750 A 104 °F (40 °C) - 10 min
Associated fuse rating
400 A aM at <= 440 V500 A gG at <= 440 V
Average impedance
0.28 mOhm - Ith 400 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole
44 W AC-131 W AC-3
Control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coilDrop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coilOperational: 0.85...1.1 Uc DC with LX4 coilDrop-out: 0.15...0.2 Uc DC with LX4 coilOperational: 85...275 V AC 50/60 Hz with LXE coilDrop-out: 0...60 V AC 50/60 Hz with LXE coilOperational: 85...418 V DC with LXE coilDrop-out: 0...45 V DC with LXE coil
Heat dissipation
8 W2.2...5.5 W
Operating time
40...65 ms closing with LX1/LX9 coil100...170 ms opening with LX1/LX9 coil40...50 ms closing with LX4 coil40...65 ms opening with LX4 coil40...80 ms closing with LXE coil6...54 ms opening with LXE coil
600...700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil655...803 VA (at 68 °F (20 °C))with LX4 coil300...350 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil300...310 VA (at 68 °F (20 °C))with LXE coil
Hold-in power consumption in VA
8...10 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil3.68...4.53 VA (at 68 °F (20 °C))with LX4 coil4.5...7.0 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil2.5...4.0 VA (at 68 °F (20 °C))with LXE coil
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
compatibility code
LC1F
IP degree of protection
IP20 front face with shrouds IEC 60529IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23...131 °F (-5...55 °C)
Ambient Air Temperature for Storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
-40...158 °F (-40...70 °C)
Operating altitude
9842.52 ft (3000 m) without derating
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed5 Gn, 5...300 HzShocks contactor open6 Gn for 1/2 sine wave (11 ms)Shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Height
8.1 in (206 mm)
Width
8.4 in (213 mm)
Depth
8.6 in (219 mm)
Net Weight
20.9 lb(US) (9.5 kg)