ISO 15407-2 ComplianceThe VABS-S4-1S-G14-K2 adheres to the ISO 15407-2 standard, ensuring compatibility and reliability in your pneumatic systems.
2
Individual Sub-BaseThis manifold features an individual sub-base, providing a stable and customizable setup for your pneumatic applications.
3
Internal Pilot Air SupplyThe internal pilot air supply enhances the manifold's functionality, allowing for precise control and efficient operation.
4
Lateral ConnectionThe manifold includes a lateral connection, facilitating easy integration with other components in your pneumatic system.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Width
26mm
Based on norm
ISO 15407-2
Mounting position
Any
Pilot air supply port
External
Operating pressure
-0.9bar 10bar
DC operating voltage range
24V
High-Quality ConstructionConstructed from high-quality materials, the VABS-S4-1S-G14-K2 ensures durability and longevity in demanding industrial environments.
Surge resistance
4kV
Current rating at 40° C
2A
Contamination level
3
CE marking (see declaration of conformity)
as per EU explosion protection directive (ATEX) As per EU low voltage directive As per EU RoHS directive
UKCA marking (see declaration of conformity)
acc. to UK EX instructions To UK RoHS instructions To UK instructions for electrical equipment
Explosion protection certification outside the EU
EPL Gc (GB)
Explosion prevention and protection
Zone 2 (ATEX) Zone 2 (UKEX)
ATEX category gas
II 3G
Type of ignition protection for gas
Ex ec IIC T3 Gc X
Explosion group of assembly
IIC
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)