Reliable PerformanceThe Festo MS6-LRP-1/4-D7-A8 is engineered to provide consistent and reliable performance, ensuring that operating pressure remains within specified limits.
2
High Cycle CountWith a service-life value of 10 million cycles, this regulator is built to withstand demanding applications and maintain its precision over time.
3
Vibration ResistanceDesigned to resist vibrations, the MS6-LRP-1/4-D7-A8 ensures that its performance is not compromised by environmental factors, making it suitable for various industrial settings.
4
Precision Diaphragm ControlThe pilot-actuated diaphragm control valve ensures precise control over output pressure, making it ideal for applications requiring exact pressure management.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Size
6
Series
MS
Actuator lock
Rotary knob with detent
Mounting position
Any
Structural design
Pilot-controlled precision diaphragm regulator
Controller function
Outlet pressure constant With secondary exhausting
5
Versatile Mounting OptionsThe regulator offers optional mounting positions, allowing for flexible installation in different setups, which enhances its versatility and adaptability in various industrial applications.
Symbol
00991973
Pressure gauge
G1/8 prepared
Operating pressure
1bar 14bar
Pressure regulation range
0.1bar 12bar
Max. pressure hysteresis
0.02bar
Flow rate of secondary venting
900l/min
Standard nominal flow rate
3000l/min
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas
Information on operating and pilot media
Ester oil < 0.1mg/m3, according to ISO 8573-1:2010 [-:-:2] Operation with oil lubrication not possible
Corrosion resistance class (CRC)
2 - Moderate corrosion stress
LABS (PWIS) conformity
VDMA24364-B1/B2-L
Storage temperature
-10°C 60°C
Temperature of medium
-10°C 60°C
Ambient temperature
-10°C 60°C
Product weight
850g
Type of mounting
Optionally: Front panel mounting Line installation With accessories