Efficient air flow management with non-return function, suitable for operating pressures up to 20 bar.
Product Modelms6n-frm-1/4-i
Material Number536977
Product ID10751
Stock on Request
Last updated: 8/29/2026
Key Features
1
Efficient Air Flow ManagementThe MS6N-FRM-1/4-I branching module ensures that air flows are directed correctly, minimizing backflow and maximizing system efficiency.
2
Non-Return FunctionEquipped with a non-return function, this module prevents backflow, ensuring that air flows in the desired direction and maintaining system integrity.
3
Wide Operating Pressure RangeCompatible with operating pressures up to 20 bar, making it versatile for various industrial applications.
4
High Flow RatesStandard nominal flow rates of 3200 l/min in the main flow direction, 2700 l/min when the outlet is at the top, and 2800 l/min when the outlet is at the bottom, catering to diverse system requirements.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Mounting position
Any
Structural design
Branching module with non-return function
Symbol
00991511
Operating pressure
0bar 20bar
Standard nominal flow rate in main flow direction 1 -> 2
3200l/min
Standard nominal flow rate outlet at top
2700l/min
Durable ConstructionBuilt with corrosion-resistant materials (CRC 2 - Moderate corrosion stress), ensuring long-lasting performance in harsh environments.
6
Temperature CompatibilitySuitable for operation within a temperature range of -10 °C to 60 °C, making it adaptable to different ambient conditions.
7
Compact DesignWeighing only 400 grams, this module is lightweight and easy to integrate into various pneumatic systems.
8
Lubricated Operation PossibleAllows for lubricated operation, which is required for further operation, enhancing the longevity of the module.
9
Compliance with ISO StandardsMeets ISO 8573-1:2010 standards for compressed air quality, ensuring clean and reliable operation.
10
Suitable for Food IndustryConforms to LABS (PWIS) and VDMA24364-B1/B2-L standards, making it suitable for use in the food industry.
Standard nominal flow rate outlet down
2800l/min
Operating voltage range AC
0V 250V
DC operating voltage range
0V 125V
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)