ABB T5H 400 PR222DS/P-LSIG In=400 4p F F: High-performance, solid-state release, front terminals, and compatible with TMax T. Ideal for demanding electrical applications.
Product ModelT5H 400 PR222DS/P-LSIG In=400 4p F F
Material Number1SDA054363R1
Product ID93878
Stock on Request
Last updated: 8/29/2026
Key Features
1
Feature1. High Electrical Durability The ABB T5H 400 PR222DS/P-LSIG In=400 4p F F is designed to withstand 7000 cycles at 60 cycles per hour, ensuring reliable performance in demanding electrical environments.
2
Feature2. Solid-State Release Equipped with a solid-state release mechanism, this circuit breaker provides fast and efficient operation, minimizing downtime and ensuring consistent performance.
3
Feature3. Front Terminal Connection The front terminal connection of the T5H 400 PR222DS/P-LSIG In=400 4p F F simplifies installation and maintenance, reducing the risk of errors and improving overall efficiency.
4
Feature4. Compatibility with TMax T Range Compatible with the TMax T range, this circuit breaker seamlessly integrates into existing electrical systems, ensuring a smooth transition to higher performance standards.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK10103A1056 9AKK108467A6707
Product Net Width
186 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
6.2 kg
Product Main Type
SACE Tmax T
5
Feature5. High Short-Circuit Breaking Capacity With a short-circuit breaking capacity of 70 kA, the ABB T5H 400 PR222DS/P-LSIG In=400 4p F F is capable of handling high current surges, protecting your electrical system from damage and ensuring continuous operation.
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
7000 cycle 60 cycles per hour
Mechanical Durability
20000 cycle 120 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 16.5 W
Rated Current (In)
400 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA (230 V AC) 100 kA (380 V AC) 70 kA (400 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (690 V AC) 40 kA
Rated Short-time Withstand Current Low Voltage (Icw)