ABB XT2N160 I R100 PMP 3P: High-performance, 3-pole moulded case circuit breaker with 690 V rated voltage and 100 A rated current, ensuring reliable electrical distribution.
Product ModelXT2N160 I R100 PMP 3P
Material Number2TFH100856R1001
Product ID91965
Stock on Request
Last updated: 9/6/2026
Key Features
1
1. High Performance and ReliabilityThe ABB XT2N160 I R100 PMP 3P is engineered to provide consistent and reliable performance in electrical distribution systems, ensuring minimal downtime and maximum efficiency.
2
2. Compliance with IEC StandardsDesigned to meet IEC standards, this circuit breaker guarantees safety and performance in a wide range of applications, from industrial to commercial settings.
3
3. Advanced Thermal ManagementEquipped with a thermomagnetic release (TMA) mechanism, the XT2N160 I R100 PMP 3P efficiently manages thermal conditions, ensuring optimal operation under various load conditions.
4
4. Versatile ApplicationSuitable for a variety of applications including industrial, commercial, and residential settings, this circuit breaker offers flexibility in electrical distribution systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
90.0 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
2.54 kg
Product Main Type
SACE Tmax XT
5
5. Enhanced Safety FeaturesFeaturing front terminals and a thermomagnetic release, the XT2N160 I R100 PMP 3P provides enhanced safety features, including automatic tripping in case of short circuits, ensuring the protection of people and equipment.
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
P
Current Type
AC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 5.2 W
Rated Current (In)
100 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip I
Release Type
EL
Remarks
ATLAS
Short-Circuit Performance Level
N
Standards
IEC60947-2 GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Plug-In Circuit-Breakers
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFH100856R1001
ABB XT2N160 I R100 PMP 3P - High-Performance 3-Pole Moulded Case Circuit Breaker | INDPRT