ABB XT2S 125 TMF 35-400 4P FF UL/CSA: Reliable, thermomagnetic release, front terminals, UL/CSA certified for safe and efficient power distribution.
Product ModelXT2S 125 TMF 35-400 4p F F UL/CSA
Material Number1SDA074779R1
Product ID85144
Stock on Request
Last updated: 9/5/2026
Key Features
1
1. Reliable Power DistributionThe ABB XT2S 125 TMF 35-400 4P FF UL/CSA ensures consistent and reliable power distribution, making it ideal for various industrial applications.
2
2. Thermomagnetic ReleaseEquipped with a thermomagnetic release (TMF) mechanism, this circuit breaker provides quick and efficient tripping in case of an overload or short circuit, enhancing safety and reducing downtime.
3
3. Front Terminal ConnectionsThe front terminal connections simplify installation and maintenance, allowing for easy access and connection of wires, reducing the risk of electrical shock or other hazards.
4
4. UL/CSA CertificationMeets both UL and CSA standards, ensuring compliance with stringent safety regulations in North America, providing peace of mind for users and regulatory bodies.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
5
5. Efficient DesignDesigned with recyclability in mind, adhering to the EN45555 standard with a recyclability rate of 58.1%, this product supports sustainable practices and reduces environmental impact.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.8 W
Rated Current (In)
35 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
35 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA (480 V AC) 35 kA (600 V AC) 22 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)