ABB XT2N 125 TMF 30-400 4p F F UL/CSA: Reliable, efficient, and safe moulded case circuit breaker for power distribution, compliant with UL and CSA standards.
Product ModelXT2N 125 TMF 30-400 4p F F UL/CSA
Material Number1SDA074750R1
Product ID84237
Stock on Request
Last updated: 9/6/2026
Key Features
1
1. Compliance with StandardsThe XT2N 125 TMF 30-400 4p F F UL/CSA is certified to meet both UL and CSA standards, ensuring it meets the highest safety and performance requirements for electrical installations.
2
2. High PerformanceDesigned for reliable power distribution, this circuit breaker offers high performance in both thermal and magnetic trip units, providing accurate overload and short-circuit protection.
3
3. Efficient DesignWith a compact design, the XT2N 125 TMF 30-400 4p F F UL/CSA minimizes space requirements while maintaining excellent electrical durability, capable of withstanding up to 25,000 cycles per hour.
4
4. Versatile ApplicationSuitable for a wide range of applications, including industrial plants, data centers, and commercial settings, this circuit breaker supports both AC and DC currents, making it versatile for various electrical needs.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
5
5. Environmental ConsiderationsABB’s commitment to sustainability is reflected in the XT2N 125 TMF 30-400 4p F F UL/CSA, which adheres to environmental standards such as UL 2799 Zero Waste to Landfill Validation and RoHS compliance, ensuring eco-friendly practices throughout its lifecycle.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.3 W
Rated Current (In)
30 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
30 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (250 V DC) 2 Poles in Series 35 kA (500 V DC) 3 Poles in Series 35 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074750R1
ABB XT2N 125 TMF 30-400 4p F F UL/CSA - High-Performance Moulded Case Circuit Breaker | INDPRT