Short Description: ABB XT2N 125 TMF 70-700 4P FF UL/CSA circuit breaker, featuring a thermomagnetic trip unit, 600V rating, and UL/CSA certification for enhanced electrical safety.
Product ModelXT2N 125 TMF 70-700 4p F F UL/CSA
Material Number1SDA074755R1
Product ID84156
Stock on Request
Last updated: 9/6/2026
Key Features
1
1. High Reliability and SafetyThe ABB XT2N 125 TMF 70-700 4P FF UL/CSA circuit breaker is designed with a thermomagnetic trip unit, ensuring reliable operation and quick response to overcurrent conditions, thereby enhancing overall safety.
2
2. Certified for Electrical SafetyThis product is certified by both UL (Underwriter Laboratories) and CSA (Canadian Standards Association), guaranteeing compliance with stringent electrical safety standards.
3
3. Versatile ApplicationSuitable for 600V applications, making it versatile for various industrial and commercial settings where high voltage protection is required.
4
4. Durable ConstructionBuilt with durable materials, this circuit breaker is designed to withstand harsh environments and maintain its performance over time.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
5
5. Easy InstallationFeaturing front terminals, the ABB XT2N 125 TMF 70-700 4P FF UL/CSA circuit breaker offers easy installation, reducing downtime and increasing operational efficiency.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.4 W
Rated Current (In)
70 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
700 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
70 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (250 V DC) 2 Poles in Series 35 kA (500 V DC) 3 Poles in Series 35 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category