ABB XT2N 125 TMF 15-400 4p F F UL/CSA: High-performance, 3-pole, thermal-magnetic trip, UL/CSA certified, ideal for reliable electrical distribution.
Product ModelXT2N 125 TMF 15-400 4p F F UL/CSA
Material Number1SDA074747R1
Product ID76573
Stock on Request
Last updated: 9/6/2026
Key Features
1
1. High Performance and ReliabilityThe ABB XT2N 125 TMF 15-400 4p F F UL/CSA is engineered to provide consistent and reliable performance in low-voltage applications, ensuring minimal downtime and maximum efficiency.
2
2. Compliance with Safety StandardsThis circuit breaker meets both UL and CSA safety standards, ensuring it is compliant with rigorous electrical safety regulations, thereby providing peace of mind for users.
3
3. Thermal-Magnetic TripEquipped with a thermal-magnetic trip mechanism, the XT2N 125 TMF 15-400 4p F F UL/CSA offers enhanced protection against overloads and short circuits, providing a high level of safety and reliability.
4
4. Versatile ApplicationDesigned for a wide range of applications, including industrial and commercial settings, this circuit breaker is versatile and can be easily integrated into various electrical systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
5
5. Durable ConstructionBuilt with high-quality materials, the XT2N 125 TMF 15-400 4p F F UL/CSA is designed to withstand harsh environmental conditions, ensuring it remains functional over an extended period.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.1 W
Rated Current (In)
15 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
15 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (250 V DC) 2 Poles in Series 35 kA (500 V DC) 3 Poles in Series 35 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074747R1
ABB XT2N 125 TMF 15-400 4p F F UL/CSA Molded Case Circuit Breaker | INDPRT